Tayota Kamri's repair since 2001
1. Operation manual and to maintenance of the car
2. Engine
3. Transmission
3.1. Coupling
3.1.1. General information
3.1.1.1. The control system of switching off of coupling at launch of the engine
3.1.1.2. Pumping of a hydraulic actuator of switching off of coupling
3.1.1.3. Adjustment of height of provision of a pedal of coupling
3.1.1.4. Check of a free wheeling of a pedal and gap of a pusher
3.1.1.5. Adjustment of a free wheeling of a pedal and gap of a pusher
3.1.1.6. Check of a point of switching off of coupling
3.1.2. Replacement of a pedal of coupling
3.1.3. Removal and installation of the main cylinder of coupling
3.1.4. The intermediate accumulator of coupling (is established since July, 2003)
3.1.5. Removal and installation of the working cylinder of coupling
3.1.6. Removal, check and installation of coupling
3.2. Mechanical transmission
3.3. Automatic transmission
3.4. Driving mechanism
3.5. Tables
4. Running gear
5. Steering
6. Brake system
7. Onboard electric equipment
8. Body
9. Schemes of electric equipment




80e768f8

3-1-1-2-prokachka-gidroprivoda-vyklyucheniya-scepleniya.html

3.1.1.2. Pumping of a hydraulic actuator of switching off of coupling

Fig. 3.4. Discharge of working liquid of a hydraulic actuator of coupling


ATTENTION
Do not allow hit of working liquid on the painted surfaces. At hit of working liquid on the painted surface wash away it immediately. Do not mix different types of working liquid. Do not reuse the merged liquid. Make sure that the level of working liquid of coupling meets standard.

Remove the flap.
Remove a cap from the union of pumping of the working cylinder of the drive of switching off of coupling and connect one end of a vinyl tube.
Place other end of a tube in transparent capacity.
a) Slowly press a coupling pedal several times.
b) At the pressed pedal of coupling weaken an inhaling of the union of pumping and let's merge working liquid.
Using special adaptation, tighten the pumping union.
Repeat the operations described in points and) and b) until in the coming-out working liquid vials of air do not cease to appear.
Tighten the pumping union the moment of an inhaling of 6-9 N · m.
Install the flap.
Bring the level of working liquid to a tag "MOVE".
Be convinced of correctness of work of coupling.

"previous page
3.1.1.1. The control system of switching off of coupling at launch of the engine
following page"
3.1.1.3. Adjustment of height of provision of a pedal of coupling