Tayota Kamri's repair since 2001
1. Operation manual and to maintenance of the car
2. Engine
3. Transmission
3.1. Coupling
3.2. Mechanical transmission
3.3. Automatic transmission
3.3.1. General information
3.3.2. Planetary transmission
3.3.3. Elements of the planetary transmission
3.3.4. Hydraulic control system
3.3.5. Safety measures in operating time with automatic transmissions
3.3.6. Check of working liquid of the automatic transmission
3.3.7. Check and adjustment of a cable of control of the valve throttle
3.3.8. Check and survey of the switch of situation parking / neutral
3.3.9. Adjustment of position of the lever of gear shifting
3.3.10. Check of the coupling of the hydrotransformer and drive plate
3.3.11. Removal and installation of the switch of situation parking / neutral
3.3.12. Removal and installation of RPM meters of the transmission
3.3.13. Replacement of the valvate block of the automatic transmission
3.3.13.1. Removal of the valvate block of the automatic transmission
3.3.13.2. Installation of the valvate block of the automatic transmission
3.3.14. Repair of the oil pump (U140E/U140F)
3.3.15. Replacement of a forward epiploon of differential of the automatic transmission (U140E/U241E)
3.4. Driving mechanism
3.5. Tables
4. Running gear
5. Steering
6. Brake system
7. Onboard electric equipment
8. Body
9. Schemes of electric equipment




80e768f8

3-3-13-2-ustanovka-klapannogo-bloka-avtomaticheskojj-korobki-peredach.html

3.3.13.2. Installation of the valvate block of the automatic transmission

Fig. 3.107. Installation of electromagnetic valves of gear shifting


Install 5 electromagnetic valves of gear shifting and fix them by 5 bolts (fig. 3.107).
Inhaling moment:
A bolt: 6,6 N · m;
B bolt: 10,8 N · m.
Bolt length:
A bolt: 12 mm;
B bolt: 45 mm.
Establish a spring and the case of the backpressure valve.

Fig. 3.105. Extraction of the case of the backpressure valve and spring


Combine a groove of the manual valve with a pin on the lever (see fig. 3.105).
Establish 17 bolts of fastening.
Inhaling moment: 10,8 N · m.

Fig. 3.108. Order of tightening of bolts of fastening of the valvate block



ATTENTION
For installation of the valve drown the valvate block, overcoming action of a spring of the piston of the hydroaccumulator and case of the backpressure valve. At first temporarily tighten the bolts noted by an asterisk in the figure 3.108 as they are adjusting.

Bolt length:
A bolt: 25 mm;
B bolt: 41 mm;
bolt of C: 45 mm.
Grease a new sealing ring of an oil filter with working liquid for the automatic transmission.
Establish a sealing ring of an oil filter.
Establish an oil filter and fix it by 3 bolts.
Inhaling moment: 10,8 N · m.
Grease a new sealing ring of the sensor of temperature of working liquid of the transmission with working liquid for the automatic transmission.
Install the sensor, a bolt and a lock plate.
Inhaling moment: 6,6 N · m.
Connect 5 sockets of electromagnetic valves of gear shifting.
Install 2 magnets in the oil pallet.
Grease bolts of fastening of the pallet with sealant.
Sealant: THREE BOND 2430 or analog.
Install the oil pallet, laying and tighten 18 bolts.
Inhaling moment: 7,8 N · m.

ATTENTION
As bolts have to sit densely, apply on them sealant and tighten in 15 min. after use of sealant.

Fill in and check working liquid of the automatic transmission.